Clients

INDUSTRY PROJECT DETAILS RESULTS ACHIEVED
Software Development
Mphasis, Bangalore

2000 -2009, Repeat jobs.

4-facilities at m5, m6, m7 and m10 of IT/Software development and Data Center. O&M at optimized holding cost. 3rd party VFD Centrifugal Chiller Efficiency Test. Facilities Design Audit.
Facilities Management, Electrical consultancy, HVAC &R Efficiency Measurements
Data Center
Intel Bangalore

2005

Product development center, IT and data center facility. Troubleshooting analysis for Lab utility equipment failures
Troubleshooting electrical fault, Harmonic analysis
Software Development
Infosys Technologies Limited, Bangalore

2003

Software development center with four building modules at Electronics City, Bangalore 14% Energy Savings verified with NO-COST implementation with the building's HVAC system through process optimization.
Energy Audit, Energy Savings
Aeronautics
Honeywell Technologies, Bangalore

2003 -2010, Repeat jobs.

Three facilities for Avionics systems, product developments and Software Development. Facing equipment tripping and failures. Designed and implemented Earthing Grid System for the facility's data center for solving Avionics lab's chronic electronic failures.
Power Quality analysis, Harmonic analysis, Earthing Pit and Grid, Electronic card failures, Zero sequence harmonic filter
Data Center
HCL Technologies Ltd, Chennai

2002

Software development facility's Data Center. Data Center's power and power quality analysis
Power Quality analysis, Harmonic analysis, Voltage sag trip
Data Center
Dell R&D, Bangalore

2007

R&D Data center facility Data Center's power and power quality analysis
Power Quality analysis, Harmonic analysis, Voltage sag trip
Software Development
Cypress Semiconductor, Bangalore

2003

IT/Software development center Data Center's power and power quality analysis
Power Quality analysis, Harmonic analysis, Voltage fluctuation
Software Development
Cisco Systems, Bangalore

2005

Software and products development center Resolved EMI problem due to which a large numbers of computer monitors were fluctuating.
EMI Shield, Power audit
Software Development
Aspect Development Bangalore

1999

Software Development Center. Installed harmonic filter for troubleshooting non functioning of Air Conditioning chiller while powered through the back up DG supply.
Harmonic Filter, DG tripping, Harmonic analysis, Voltage sag
Software BPO
Sobha Renaissance, Bangalore

2005

IT/ BPO facility's detailed facility analysis. Energy and total power management
Power audit, Voltage sag