PROJECT DETAILS
500TPD Wire mill and wire ropes. 50TPD bright bars and 7TPD conveyor chord. 2nos 10mw CPP power plant. Root cause analysis of frequent PLC/ MMI/ VFD/DC drive tripping and failures including SQIM/ SRIM/ DCM and bearing.
RESULTS ACHIEVED
12% Energy Savings verified with harmonic filter installation. Debottlenecked capacity limitation and enhancesproduction. Eliminated all failures. Supplied 3425A and 2375A harmonic filters.